Ultraviolet Sterilizer≠Filter |
The Ultraviolet Sterilizer to
aim at exclusively the living creature sexually transmitted disease
poison disinfects the appropriation apparatus, it is to can't away
with or the absorption has the material of the physics and chemistry.
The Ultraviolet Sterilizer equips need to
import in place ahead a disinfection for adding ex- class filtering
equiping toing do away with physics, chemistry material and miscellaneous
quality,toing guarantee the ultraviolet ray disinfects as to it's
can machine disinfect the object put out the germ effect can attain
best.
Operation method attention and maintain to replace the announcements:
First time and shut down each time after replacing the ultraviolet
ray light tube, use the ultraviolet ray disinfect the machine open
into first the water valve door duct into water to ultraviolet ray
to disinfect the machine slowly inner part, while openning into water
polo valve, need to be opened slowly can't a the time arrive the ball
valve to bottom, in order to prevent enter water pressure dint and
momentums take care of the quartz set broken up!But leads to whole
machine can't work.Open to just open a water polo valve after five
minutes in empress in total power supply, needs to be noticed on the
discharge and can't exceed to disinfect the machine of design discharge.
Everyday tour control cabinet ultraviolet ray light tube work instruction
light and ultraviolet ray light tube work situation and take into
the record.
The Ultraviolet Sterilizer outside the design is last
besides simple light the tube replace to maintain, also the automatic
electric circuit cruises the device of , being to disinfect the light
tube break down, control the electric circuit in the cabinet cruise
the will shine automatically red light and serial numbers erupt to
make a noise to ring, toing remind that the user maintains to replace,
toing guarantee in the middle of using insure to disinfect the result.
The light take care of at not the year replace damage, measure first
the light the tube whether intact?If the light tube would be bright
and did not damage but the automatic electric circuit cruises the
equips to make a noise and the red instructions the light is bright,
please replace to control the circuit board inside the cabinet.
While replacing the circuit board or lights tube, close first the
total power supply, in order to prevent circuit board or light tube
damage.
If the light tube hases damaged to please replace the light the tube
and take in to record time.For the purpose of ultraviolet ray light
take care of when the year replaces do not replace temporary, wait
for its work time to replace after attaining 8000 hours.
If discover When the single side( the light takes care of and the
set takes care of entrance) in corpus seep into, the check seeps into
place and take into the tight and big nut in lock.
Is since the quartz set takes care of the inside run off, enunciation
is quartz set the tube is already damaged, please the close in front
and back ball valve and power supplies, put to fuck the internal water
in whole machine such as the water, open the big nut after drawing
out the ultraviolet ray light the tube, take out a tube, replace it,
press to dismantle to pack the sequence pack back, packing to open
first the ex- ball valve after returning, checking whether have seep
into, if have no to seep in to can take care of the ultraviolet ray
light to pack back, after turning power on, just after openning ball
valve, can't once sex arrive the ball valve to bottom! |
|