1. If there is water leakage on either side of the nuts:
Change the rubber ring.
2. If there is any leakage in the tube: Check the Quartz tube, replace
it if there is any damage on it.
3. If there is any leakage at water IN/OUT: Shut down water supply,
unfasten the connector, put some water-proof tape on the connector
then put it back.
4. If UV tube does not light up: Check power indicator on blaster
is on or not, if it is not, please replace fuse, If the UV tube does
still not light up and the warning beep it beeping, please change
the UV tube. |
|
The economic type fluid matter of
UV- C disinfects the container data: |
Model number |
watts |
Electricity unit volts |
Electricity unit Hz |
Output power |
UV chamber Material |
UV DosageuW/cm2 |
YK-UV4W-M |
4W |
120V/230V |
50Hz/60Hz |
36mA |
304# |
>30000 |
YK-UV6W-M |
6W |
120V/230V |
50Hz/60Hz |
42mA |
304# |
>30000 |
YK-UV11W-M |
11W |
120V/230V |
50Hz/60Hz |
50mA |
304# |
>30000 |
YK-UV16W-M |
16W |
120V/230V |
50Hz/60Hz |
72mA |
304# |
>30000 |
YK-UV25W-M |
25W |
120V/230V |
50Hz/60Hz |
113mA |
304# |
>30000 |
YK-UV30W-M |
30W |
120V/230V |
50Hz/60Hz |
136mA |
304# |
>30000 |
YK-UV55W-M |
55W |
120V/230V |
50Hz/60Hz |
250mA |
304# |
>30000 |
|
Model number |
Flow Rate in Clear, clean water |
Flow Rate in Clear,Di, or RO water |
In/Out Connect size(Inch) |
Max pressure (kg) |
Useful life(hrs) |
LED
Warning system |
YK-UV4W-M |
0.2GPM |
0.25GPM |
1/4" |
6kg |
6000 |
yes |
YK-UV6W-M |
0.4GPM |
0.5GPM |
1/4" |
6kg |
8000 |
yes |
YK-UV11W-M |
0.8GPM |
1GPM |
1/4" |
6kg |
8000 |
yes |
YK-UV16W-M |
1.6GPM |
2GPM |
1/4" |
6kg |
8000 |
yes |
YK-UV25W-M |
4.8GPM |
6GPM |
1/2" |
6kg |
8000 |
yes |
YK-UV30W-M |
6.4GPM |
8GPM |
1/2"~3/4" |
6kg |
8000 |
yes |
YK-UV55W-M |
9.6GPM |
12GPM |
3/4"~1" |
6kg |
8000 |
yes |
|
|
The characteristics of Ultra Violet
ray Water disinfect device Introduction: |
It is known that the most convenient and low cost method
to kill germs is using ultra violet ray within solar ray. Human being
was using it everyday since ancient but they didn’t know it is ultra
violet ray.
There are more than 200 years since ultra violet ray was found but
no one knew it could be used on disinfecting germs until 1877, doctor
Niels Ryberg Finsen,
A Danish Scientist who found out to expose some specified skin disease
under solar ray would be healed much faster, who spent most of his
life wanted to find out this possibility.
Ultra Violet ray is an invincible light within the solar ray separate
into 3 band: A (UVA), B (UVB), C (UVC); The most effective band is
C band (UVC ) which wave length is 253.7 nM |
|
What are the advantages of Ultra
Violet disinfect device: |
1. It can kill algae, fungi, germs and virus they are
all in the water.
2. No side effect will be remained. There will be no toxic, pollution
or residue left after using this device.
3. Easy to use.
4. Can be used at most of environment such as hospital, food industry,
environment protection industry, medicine industry and biochemical
research etc.
5. Low cost. |
|
Installation and user’s manual: |
1. To avoid the device falling down, please use a clip
to fix it properly.
2. Plug the UV light tube into blaster, which has 4 sockets then insert
through nut.
3. Connect water inlet and outlet to water supply, visual inspect
if there is any water leakage, do not supply power unless there is
no any leakage.
4. Warning beep sound will occur and warning indicator will light
if the UV tube is damaged or misplaced. |
1. Do not see the UV tube directly when the device is
functioning to avoid hurt your eyes.
2. If you install the device vertically, please keep water outlet
is higher than inlet to reduce the speed of water flow as well as
to increase the effect of UV ray.
3. Please add limitation unit if the water pressure or flow is too
high.
4. Please add an one-way valve if water pressure exceeds 3kg in order
to protect the Quartz tube.
5. If the constant shut electromechanical valve is used together,
please connect this valve to water inlet.
6. Please add a filter in front of water inlet if the water is too
muddy.
7. Clean Quartz tube every 4-6 month and check is there is any damage. |
1. Shut down power, take out UV tube, unscrew the nuts
on both side, take out quartz tube, clean the tube, put the tube back
where it was, fasten the nuts, put in UV tube then turn power on.
(Do not forget the rubber ring)
2. Use PH7 soap or lemon acid to clean the Quartz tube, use alcohol
wipe the tube after you clean it. Check if there is any water leakage
after installation. |
|